DSP Technology:The advanced DSP digital control technology enables UPS more stable performance.
Environment Friendly: This UPS is eco-designed and manufactured to meet the pollution control requirement of Electronic Products, which means it will cause no harm to environment and human beings in normal usage.
Active input power factor correction (PFC):Digitalized control of the PFC enable the UPS to keep input power factor above 0.99 to prevent possible electric grid pollution and meanwhile mostly save the cost.
Wide range of input voltage and frequency:We intentionally widen the range of input factors to make sure the UPS can apply to various environment, which will effectively sustain the battery charging even in unstable power environment so that the service life of the UPS could be obviously prolonged.
Zero power switch delay:When the utility power fails, UPS will automatically switch from AC mode to battery mode with no delay, which ensures stable power supply of operating system.
Active Load Management: This technology allows the UPS to be set up at a fixed 50Hz or 60Hz output, while it also can intelligently monitor power usage and automatically sheds and reconnects loads in order to prevent generator overload.
Sufficient Expansion Slots: The pre-allocated smart slots enable flexibility RS232 software environment monitoring cards.
The load power factor is 0.8:It adapts the features of most current electric equipment and elevates the load-bearing capacity of the machines.
Generator Supportable: The wide range of input voltage and frequency can effectively separate the harmful electric wave produces by the generators and provide safe and reliable power supply.
Large-screen LCDWith English language of LCD display, It will show the UPS working status by the figures or code directly. And it could be estimated the failure causes, location quickly by reference of fault information polling list, which will make the UPS maintenances much more convenient.
Perfect protection Perfectly system protection functions: It has AC over-voltage, under-voltage, output over-voltage, under-voltage, output overload, short circuit protection, inverter, rectifier over-temperature protection, voltage under-voltage warning, battery over charging protection and other protections in one to ensure the system to operate stably and reliably.
MODEL | SG1K | SG2K | SG3K | SG6KS | SG10KS |
Rated capacity | 1KVA/800W | 2KVA/1600W | 3KVA/2400W | 6KVA/4800W | 10KVA/8000W |
Input | Voltage | 60-138Vac or 115 - 300Vac (optional) |
Frequency | 40-60Hz / 50-70Hz |
Power factor | 0.99 |
Output | Voltage | 110/120V/220/230/240Vac(1±2%) (optional) |
Frequency | Synchronize with utility power(utility mode); 50 / 60Hz ± 0.2Hz(battery mode) |
On-load factor | 0.8 |
Overload rating | 125% overload,1min |
Battery | Type | Valve-control lead acid maintenance-free battery |
Rated voltage | 36V | 72V | 96V | 192V (without battery) | 192V (without battery) |
Transfer time | 0 |
Operating environment | Humidity: 20%-90%, Temperature:0oC-40oC |
Size (WxDxH)mm | 350 x 144 x 229 | 424 x 190 x 328 | 424 x 190 x 328 | 260x533x501 | 260x533x501 |
Net Weight(kg) | 11.5 | 22.2 | 26.3 | 18kg | 25kg |